Liquid level, pressure and temperature monitoring for tanks.

LoRA based remote monitoring of liquid level, pressure and temperature for (e.g.) tanks, ground water, wells or depth and temperature monitoring in running or open water.

Tools

Download our free business value calculator to determine the potential benefits of your project

Download

Device partner

Product description

The Decentlab DL-PR 26 sensor, measuring liquid levels and temperature allows for remote monitoring. Through LoraWAN connectivity monitoring can be provided for (e.g.): outdoor remote monitoring, level / depth monitoring in tanks for liquids, groundwater level monitoring, level / depth monitoring in wells, water depth and temperature monitoring in running or open water and relative pressure measurement. It is easy to install and fully integrated with the Withthegrid online application for remote monitoring and controlling the device.

 

  • Easy installation
  • LoRaWAN Class A protocol
  • Data is visualized via the Withthegrid online application
  • Fully integrated with the Withthegrid application for sending commands and changing parameters
  • Unattended real-time monitoring for several years without replacing batteries.
  • Robust polycarbonate enclosure: weatherproof, impact-, UV-resistant (IP67). 
  • Standard alkaline (C-type) batteries. 
  • CE compliant, Radio Equipment Directive (RED) 2014/53/EU.
  • Place and measure: no setup required.

Software functionality

The online Withthegrid application is designed to give the user a complete overview of asset performance. You can view historic performance, set thresholds and alarms and enrich the overview with manual measurements from the field. 

 

Deep integration with this liquid level and temperature sensor allows you to: 

  • Automatically detect anomalies 
  • Have a real-time status of liquid: level/depth/temperature
  • Relative pressure measurement
  • Monitor follow-up actions for your personnel

Device specification

Device Specifications

Dimensions 135 x 81 x 70 mm (not incl. cable/sensor)
Version 840g incl. batteries and sensor (710g excl.)
Enclosure Polycarbonate; weatherproof, impact-, UV-resistant (IP66/IP67).   Pressure equalizer plug with PTFE membrane (IP68).

 

 

 

Pressure Sensor
Operating Principle Piezoresistive pressure measurement
Measurement Range 0.0 … 1.0 bar
Resolution 0.000030 bar / 0.3 mm (= full scale / 32768)
Linearity / precision max. ±0.15 % of full scale
Total error band (max. deviation within 0 … 50 ºC) max. ±0.5 % of full scale
Temperature Sensor
Resolution 0.003125 ºC
Accuracy ±2 ºC (typical)